PAC International RSIC-Joist Isolator

The PAC International RSIC-Joist Isolator is a resilient cap that seats over the top of a wood joist so the subfloor above is decoupled from the joist framing below. It preserves floor buildup height while breaking the direct impact and vibration path between finished floor and joist — the workhorse detail for high-IIC wood-framed floor assemblies in multifamily and residential retrofits.

  • True Joist Decoupling: Seats over the joist top so subfloor screws land in the isolator's steel cap, never into the joist itself — eliminating the rigid bridge that defeats most retrofits.
  • Zero Extra Floor Height: Adds only the isolator's cap thickness to floor buildup — the go-to option when finish-floor height is fixed by doors, transitions, or code.
  • Retrofit-Friendly: Drops onto exposed wood joists during rough-in — no reframing, no floating floor cassette, no concrete topping required.
  • Consistent Layout: Set one isolator per joist at the manufacturer's recommended on-center spacing so load and deflection stay uniform across the floor plate.
$2.99
/ isolator

Online orders up to 4,999 pieces. For anything larger, call (415) 864-4440 and we'll price the project with you.

Volume pricing

$2.99 per isolator. Order 250+ isolators and pay $2.89 per isolator — an extra $0.10 off per isolator for each additional 250 isolators, down to a $2.10 per isolator floor.

Discounts apply automatically in the cart and count boxes and cases toward the total.

Authorized PAC International DealerUL-compatible assembliesLocal pickup: SF, San Leandro, LA
Product Specs

RSIC-Joist Isolator Specifications

Application
Wood-joist floor decoupling under subfloor
Overall width
2.13 in.
Overall height
1.93 in.
Base thickness
0.43 in.
Isolation element
Molded rubber U-cap that seats over the joist top
Layout
One isolator per joist at project-engineered on-center spacing (typ. 16 in. o.c.)
Mounting
Seats over joist top — subfloor screws land in the isolator's cap, never the joist
Compatible framing
Nominal 2× wood joists — I-joists on request
Companion Component

Rockwool Safe'N'Sound R11

R-Value
R-11
Material
Stone wool (basalt rock + recycled slag)
Framing fit
2×4 stud and joist cavities, 16" or 24" o.c.
Density
Higher than standard fiberglass batt
Fire performance
Non-combustible, melting point ~2,150°F
Water repellency
Water-repellent, won’t support mold growth
Install method
Friction-fit; cut with a long serrated knife
Coverage
Approx. 60 sq ft per bag
Quantity Calculator

RSIC-Joist Isolator Project Calculator

Enter your surface square footage. We'll return a clip, channel, and screw count for your project — calculations run on our servers so estimates stay accurate as our field data improves.

Assembly STC (estimated)
57

Adds MLV over Good for a denser limp-mass layer.

Assembly datasheets
Good STC 52Better STC 57Best STC 65

One isolator per joist at the manufacturer's on-center spacing. Confirm layout with an acoustic engineer and add a 10% coverage buffer for cuts and re-work.

Estimated Materials
—Clips needed
Screws for clips—
Indicative only. Final quantities vary by framing spacing and access.
Sound Performance

IIC Gauge

Compare how the RSIC-Joist Isolator performs across assembly tiers. Select an assembly below to see the resulting IIC score.

Joist Isolators + Rockwool + MLV + double subfloor with Green Glue between layers.

IIC59
080
What the score means
  • STC 30-39: Loud speech clearly audible next room.
  • STC 40-49: Loud speech muffled — normal residential wall.
  • STC 50-59: Loud speech barely audible; suitable for offices & multi-family.
  • STC 60+: Approaches studio-grade isolation.
Product Comparison

How RSIC-Joist Isolator compares

ModelPrimary UseFramingTypical LayoutIsolation Element
RSIC-Joist IsolatorthisDecouple subfloor from wood joistsWood joists (2× and I-joist)One isolator per joistMolded rubber isolator in steel cap
IFB1Under sleepers / subfloor over deckConcrete or continuous deckProject-engineered gridMolded rubber pad
RSIC-UUniversal clip for specialty framingMixed / non-standardProject-specificMolded rubber isolator
Downloads

Data Sheets & Guides

PAC Isolation Products — Data Sheets Library
FAQ

RSIC-Joist Isolator — Common Questions

The Joist Isolator seats directly over each wood joist so subfloor fasteners never touch the joist. IFB blocks sit under sleepers or a plywood raft on a project-engineered grid. Choose the Joist Isolator when the floor is stick-framed and you want to keep buildup height minimal; choose IFB when the floor is over concrete deck or when a grid layout is easier than a per-joist detail.