The RSIC-SI-X 1.5 CRC is a ceiling-only isolation clip used at the intersection of a 1-1/2 x 1/2 in, minimum 16 ga cold-rolled channel (CRC) above and a 7/8 in, 25 ga hemmed-edge drywall furring channel below. Its top clip snaps onto the CRC and is screwed tight, so the hanger wires and any vertical strut can stay hard-connected to the structure while the spring-and-rubber isolator decouples the lower furring channel and gypsum ceiling at every specified crossing. It ships pre-assembled and pre-calibrated, and it is not adjustable.

  • Attaches to the cold-rolled channel, not the structure: The top clip snaps onto the 1-1/2 x 1/2 in, minimum 16 ga CRC and is screwed tight to it. There is no generic wood, steel or concrete fastener schedule for this clip — the CRC and its wires and strut are what connect to the structure.
  • Spring and rubber in one calibrated unit: Each clip combines a coil spring with a rubber isolator, shipped pre-assembled and pre-calibrated. Total deflection is 0.5 in and the clip is not adjustable in the field.
  • 16 x 48 in maximum layout: Clips sit at a maximum of 16 in o.c. along the crossing grid, with CRC framing at a maximum of 48 in o.c. That grid is the same for one or two layers of 5/8 in gypsum board.
  • Colour-coded spring capacities: White 7 lb for edge, corner and infill where additional support is needed; Blue 13 lb for field and edge; Red 26 lb primarily for the field. The final colour schedule follows the project submittal.
  • A shallow CRC alternative — not a long-span product: Nominal minimum cavity is 3-1/2 in with no maximum. For heavier systems PAC directs you to increase the number of isolators and channel, not to overload a spring.
Price Available on Request

Contact for pricing

Special-order item. We confirm current pricing, lead time (typically 3–10 business days, longer for custom sizes), and the material, size and finish options available — plus supply-only vs. professional-install pricing. Nothing is charged until you approve the estimate.

Call (415) 864-4440

Prefer a form? Open the estimate request with this product filled in.

Authorized PAC International DealerCeiling-only CRC-to-furring intersection clipLocal pickup: SF, San Leandro, LA
Product Specs

RSIC-SI-X 1.5 CRC Specifications

Use on ceilings
Yes
Use on walls
No
Type
Spring and rubber isolation clip at the CRC / furring-channel intersection
Upper connection
Top clip snaps onto 1-1/2 x 1/2 in, minimum 16 ga cold-rolled channel and is screwed tight to it
Lower connection
7/8 in, minimum 25 ga hemmed-edge drywall furring channel snaps into the lower part
Isolation
Spring isolation: yes · Rubber isolation: yes · Double deflection: yes
Total deflection
0.5 in (family summary). The detailed capacity schedule states design load at 3/8 in deflection from free height — a different reference condition
Acoustical design load
White 7 lb · Blue 13 lb · Red 26 lb per isolator (detailed schedule)
Structural limit
Do not exceed 36 lb pull and shear per clip — a structural limit, not an acoustic rating
Maximum layout
16 x 48 in o.c., the same for one or two layers of 5/8 in gypsum board
Rough density
About 1 clip per 5.33 sq ft at the maximum grid — a sanity check only
Adjustable
No — shipped pre-assembled and pre-calibrated
Cavity
Minimum 3-1/2 in nominal · no maximum
Temperature
Interior use only, 40–100 °F (4.4–37.8 °C)
Construction
New construction and retrofit
Furring channel splices
Minimum 6 in overlap at mid span between clips — never on a clip — with two 7/16 in framing screws or double-wrapped 18 ga tie wire
Companion Component

Making the connection

1 — Structure and anchors
Approved structure with anchors by others, suited to the substrate and the load at each hanger point
2 — Hanger wires and vertical strut
Hard-connected to the structure and to the suspended CRC — these stay rigid; the isolation happens at the clip below them
3 — Cold-rolled channel (CRC)
1-1/2 in wide x 1/2 in deep, minimum 16 ga, meeting or exceeding SSMA minimums
4 — RSIC-SI-X 1.5 CRC clip
Top clip snapped onto the CRC and screwed tight; spring and rubber isolator inside
5 — Drywall furring channel
7/8 in deep, minimum 25 ga with hemmed edge, 1-1/4 in top and minimum 2-1/2 in bottom width, snapped into the clip's lower part
6 — Gypsum board
Installed perpendicular to the furring channel with a minimum 1/4 in perimeter gap sealed with acoustical caulk
Intersection Estimator

RSIC-SI-X 1.5 CRC Preliminary Ceiling Estimate

Built for ceilings. One clip goes at every specified crossing of the cold-rolled channel above and the 7/8 in furring channel below, so the count is CRC runs multiplied by clip positions. PAC's maximum layout is 16 x 48 in o.c., and it is the same for one or two layers of 5/8 in gypsum board.

Spring colour and load
White — 7 lb
Edge, corner and infill where additional support is needed
Blue — 13 lb
Field and edge
Red — 26 lb
Primarily field

Colours are pre-calibrated and are distributed across the ceiling — field, edge, corner and infill positions each carry a different tributary load, so the final colour schedule follows the PAC or project submittal rather than one colour everywhere. The 26 lb rating is the design load at 3/8 in deflection from free height; the family summary's 0.5 in figure is total deflection, a different reference condition.

Source note: PAC's submittal front page summarises the range as 7–25 lb, while the detailed capacity schedule and the spec guide's product limitations both list 7 / 13 / 26 lb. The detailed schedule is used here. Separately, the spec guide's "do not exceed 36 lb pull and shear" is a structural limit — never treat it as an allowable acoustic load. Both the spring rating and the structural limit must be satisfied.

Product Comparison

How RSIC-SI-X 1.5 CRC compares

ModelUseUpper connectionLower channelMaximum layout
RSIC-SI-X 1.5 CRCthisCeilings onlySnaps and screws onto 1-1/2 x 1/2 in, min. 16 ga cold-rolled channel7/8 in, min. 25 ga hemmed-edge furring channel16 x 48 in o.c. (1 or 2 layers of 5/8 in gypsum)
RSIC-SI-XPer its own listingPer the RSIC-SI-X installation guide7/8 in furring channelPer its own guide
RSIC-1Walls and ceilings per its own listingFastened to the framing member7/8 in furring channelPer the RSIC-1 installation guide
Downloads

Data Sheets & Guides

PAC International — RSIC-SI-X CRC product page
PAC International Clips — Data Sheets Library
FAQ

RSIC-SI-X 1.5 CRC — Common Questions

The top clip snaps onto a 1-1/2 x 1/2 in, minimum 16 ga cold-rolled channel and is then screwed tight to that channel. It is not fastened directly to joists, studs or concrete. The spec guide carries one generic sentence saying the clip fastens to the underside of the structure, but its own detailed instructions and the installation guide both describe the CRC connection, so that is what we follow.