(415) 864-4440
Acoustic Panels

Pyramid Acoustic Panel

High-performance pyramid-profile absorption for reflective rooms.

Engineered from open-cell melamine foam, the Pyramid Acoustic Panel is a high-performance echoic absorber built to reduce reverberation, control echo, and improve speech clarity in acoustically reflective rooms. The pyramid profile expands surface area and creates multi-angle sound interaction, driving effective scattering and absorption across mid–high frequencies where reflections most impact intelligibility.

Pricing
Contact for Pricing

Send us the room dimensions and target reverb time — we’ll return a coverage plan and estimate.

Pyramid Acoustic Panel — product hero image
Highlights

Why specify the Pyramid Acoustic Panel

  • Reverb Control

    Reduces flutter echo and reverberation for clearer speech and improved room clarity.

  • Class A Fire Rated

    Meets ASTM E84 Class A — safe for commercial, hospitality, and studio environments.

  • Lightweight Install

    Direct-mount to walls or suspended from ceilings with minimal hardware.

  • Fiber-Free Core

    Open-cell melamine foam is fiber-free and thermally stable — no shedding or airborne particulates.

Sound Absorption

NRC Gauge

Independent absorption testing on our melamine foam. NRC represents the average absorption from 250 – 2000 Hz — the range that carries most speech and music energy.

NRC
NRC 0.80 of 1.00 — strong absorption for White finish at 1.5 inch thickness
0–0.30Reflectiveabsorption tier
0.30–0.60Modestabsorption tier
0.60–0.85Strongabsorption tier
0.85+Studio-gradeabsorption tier
SAA
0.78
Mounting
Type A
Source

Absorption results tested in accordance with ASTM C423-09a — independent third-party acoustic lab report supplied by the manufacturer.

NRC = Noise Reduction Coefficient, the average of the 250, 500, 1000, and 2000 Hz absorption coefficients rounded to the nearest 0.05. SAA = Sound Absorption Average across twelve one-third-octave bands (200–2500 Hz). Mounting follows ASTM E795 (Type A = direct-to-hard-surface).

What the score means
  • NRC 0.00–0.30: Reflective surface — will not meaningfully reduce echo.
  • NRC 0.30–0.60: Modest absorption — some reverb reduction.
  • NRC 0.60–0.85: Strong absorption — noticeable clarity and comfort gains.
  • NRC 0.85+: Studio / broadcast-grade absorption.

Higher NRC = more sound absorbed on impact. NRC only measures absorption within a room; it is not a soundproofing (transmission-loss) rating.

Sound absorption coefficient (Sabins / ft²) by finish, thickness, and frequency band.
FinishThickness125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 HzSAANRCMount
White1.50"0.170.280.840.991.031.040.780.80A
2.00"0.230.481.081.191.161.110.971.00A
3.00"0.450.871.261.071.061.101.051.05A
Light Grey1.50"0.170.280.860.991.021.020.790.80A
2.00"0.200.511.051.051.031.050.910.90A
3.00"0.360.901.241.041.021.091.051.05A
ObsidianOfficial test results pending; performance expected to align with our light grey melamine foam.1.50"0.170.280.860.991.021.020.790.80A
2.00"0.200.511.051.051.031.050.910.90A
3.00"0.360.901.241.041.021.091.051.05A
Specifications

Product Specs

Panel size
24" × 24" (4 sq ft)
Thickness
1.5", 2", or 3" options
NRC
1.5" 0.80 · 2" 0.90–1.00 · 3" 1.05
Material
Flexible Open-Cell Melamine Foam
Density
Light Grey 0.56 ±0.09 lb/ft³ · Natural 0.47 ±0.13 lb/ft³
Fire rating (Light Grey)
ASTM E 84 Class A · FSI 10 / SDI 55
Fire rating (Natural)
ASTM E 84 Class A · FSI 5 / SDI 20 · CAN/ULC S102 · FSI 0 / SDI 30
Minimum service temp
−40 °F
Maximum service temp
350 °F
Storage
Keep dry, flat, or on core · 40 – 90 °F
Structure
Fiber-free, thermally stable
Dimensional drawing — 24" × 24" panel, 2" thickness, 2" × 2" pyramid base.
Installation

Install guide

Six-step install guide — from identifying reflection points to adhesive mounting and final tuning.
Data Sheets

Downloads & documentation

Manufacturer datasheets, install instructions, fire-rating test summaries, and certifications for the Pyramid Acoustic Panel.

PDF Bundle
Grab the full document pack for the Pyramid Acoustic Panel

Includes 6 technical PDFs · install guide available separately.

Download install guide (PDF)
What's included (7 files)
FAQs

Frequently asked

  • Do acoustic panels soundproof a room?

    No — these panels absorb sound within a room to reduce echo, reverberation, and flutter. Blocking sound between rooms is a separate problem solved with mass, decoupling, and damping (see our Soundproofing Materials).

  • What thickness should I choose?

    Use 2" for general echo control in speech-range rooms, 3" for balanced broadband absorption, and 4" (or deeper wedge/pyramid profiles) when stronger low-mid response matters — home theaters, studios, and reference rooms.

  • How many panels do I need for my room?

    Coverage depends on room size, surface reflectivity, and target reverb time. A common starting point is 15–35% of the reflective surface area. Send us dimensions and use case and we'll return a coverage plan.

  • Where do panels install best?

    First-reflection points on the walls closest to speakers or the sound source, opposite the seating position, plus the ceiling directly above the listener. Corners and boundaries are for bass traps, not panels.

  • Can these be mounted on any surface?

    Yes — drywall, wood, concrete, and metal all work. Use adhesive, impaling clips, Z-clips, or cable suspension depending on the panel weight and finish requirements.

Guidance

Not sure how many you need?

Share the room dimensions and how the space is used — we’ll return a treatment plan with panel count, placement, and product mix targeted to your reverb-time goal.

Install