PAC International RSIC-1 BACKER
The PAC International RSIC-1 Backer is a heavy-duty resilient backing mount used inside a conventional RSIC-1 sound-isolated wall wherever substantial objects have to be attached. Two different jobs are involved, and they use different parts: RSIC-1 clips with their approved furring channel form the repeating grid that supports the gypsum board, while RSIC-1 Backer mounts fasten to the face of the wall studs at localized backing elevations and carry a separate steel backing track. That track — minimum 16-gauge steel, 6" wide and 1-1/4" deep — becomes the mounting surface for heavy items once the gypsum board is up. The Backer is not intended to secure gypsum board and it does not accept 7/8" hat or furring channel. PAC's own examples of what it supports include cabinets, chalkboards, projector screens, handicap grab bars, lockers, TV wall mounts, handrails and library shelves, in new construction or retrofit.

- The Problem It Solves: Screwing a cabinet, TV mount or grab bar straight through the isolated finish and into the studs rigidly ties the mounted item back to the structure. The RSIC-1 Backer gives that item its own resiliently mounted steel backing instead.
- Works With The RSIC-1 Wall — Not With Hat Channel: RSIC-1 clips and their approved furring channel still carry the gypsum board. The Backer is a separate, localized element: it does not accept hat or furring channel and is not intended for gypsum-board securement.
- Required Backing Track And Fastening: A steel backing track of minimum 16 gauge, 6" wide and 1-1/4" deep — meeting or exceeding SSMA minimum requirements — attaches over the Backers with four framing screws into each Backer (minimum 1/2" pan-head self-drilling framing screws).
- Standard Capacity And Layout: 108 lb acoustical design load per isolator on the standard model, with 3 mm total deflection (double deflection, 1.5 mm each). On walls, install a Backer on every stud crossed by the backing track, never more than 48" on center, with all Backers in a row in the same horizontal plane.
Online orders up to 4,999 pieces. For anything larger, call (415) 864-4440 and we'll price the project with you.
Volume pricing
$14.95 per clip. Order 250+ clips and pay $14.80 per clip — an extra $0.15 off per clip for each additional 250 clips, down to a $13.99 per clip floor.
Discounts apply automatically in the cart and count boxes and cases toward the total.
RSIC-1 BACKER Specifications
- Model sold here
- Standard RSIC-1 Backer (not HD/DD)
- Application
- Localized isolated backing for heavy wall-mounted items in an RSIC-1 wall
- Acoustical design load
- 108 lb per isolator (RSIC-1 Backer HD/DD is a different model rated 216 lb)
- Deflection
- 3 mm total — double deflection, 1.5 mm each
- Dimensions
- 4 in wide × 6 in long × 1 5/8 in deep
- Attaches to
- Face of the wall studs — never to hat or furring channel
- Supports
- Minimum 16-ga steel backing track, 6 in wide × 1 1/4 in deep
- Fasteners to wood
- Minimum #8 × 2 1/2 in screw
- Fasteners to steel
- Minimum #8 × 1 5/8 in screw
- Never fasten with
- Nails — approved screws only
- Wall layout
- Every stud crossed by the backing track; spacing not to exceed 48 in o.c.; all Backers in a row in the same horizontal plane
- Not intended for
- Securing gypsum board
- UL
- UL Listed under CLBV7.R16638 for the specified U300/U400/V300/V400/W400 wall series with corresponding RSIC steel framing members, attached to stud faces, not intended for gypsum-board securement, total installed depth no greater than adjacent framing members and furring channels
Steel backing track
- Minimum gauge
- 16 gauge steel
- Width
- 6 in
- Depth
- 1 1/4 in
- Standard
- Meets or exceeds SSMA minimum requirements
- Fastening to each Backer
- 4 framing screws — minimum 1/2 in pan-head self-drilling
- Not acceptable
- 7/8 in 25-gauge hat / furring channel — that channel belongs to the RSIC-1 clip drywall grid, not to the Backer
RSIC-1 Backer Preliminary Estimate
RSIC-1 Backer quantities are not estimated from wall square footage. A Backer is installed on every stud crossed by the planned steel backing track, with spacing never exceeding 48" on center, and every Backer carrying one track row must sit in the same horizontal plane.
An 8-foot run aligned stud to stud across 16"-o.c. framing crosses 7 stud locations (0, 16, 32, 48, 64, 80, 96 in), so one row uses 7 Backers and two rows use 14.
A backing run that crosses three studs uses 3 Backers per row — 6 Backers if the design calls for two track rows.
Preliminary material takeoff only. Final backing-track gauge, fasteners, bracket count, attachment layout and load capacity must be verified for the mounted item, framing, substrate, applicable codes and project-specific structural requirements.
How RSIC-1 BACKER compares
| Model | Primary Role | Connects To | Acoustical Design Load |
|---|---|---|---|
| RSIC-1 BACKERthis | Localized heavy-load backing inside an RSIC-1 wall | Minimum 16-ga steel backing track, 6 in × 1 1/4 in | 108 lb per isolator |
| RSIC-1 BACKER HD/DD | Heavy-duty / double-capacity backing mount — a different model | Minimum 16-ga steel backing track, 6 in × 1 1/4 in | 216 lb per isolator |
| RSIC-1 | Repeating resilient clip that supports the gypsum-board plane | Approved furring channel | Not a heavy-item backing mount on its own |