(415) 864-4440
PAC International Clips

PAC International RSIC-WFI

RSIC-WFI is a wall-frame isolation system that combines rubber-isolated anchors with a continuous fiberglass support pad to separate a wall's top and bottom framing from the adjoining structure. Individual molded-rubber RSIC-WFI isolators sit at the designed anchorage points, and a continuous 1/2 in RSIC-FGP fiberglass pad runs beneath (or above) the wood plate or steel track, supporting the framing between isolators. It isolates the framing itself — it does not receive furring or hat channel and does not carry gypsum board.

  • Isolates the wall framing, not the board: RSIC-WFI works at the wall's structural boundaries — the floor-wall and ceiling-wall intersections. It does not receive furring or hat channel, and gypsum board is never fastened to it.
  • Two parts, one system: Molded-rubber RSIC-WFI isolators at each designed anchorage point, plus continuous 1/2 in RSIC-FGP fiberglass pad. PAC states the FGP supports the wall framing between isolators and is required at the base of wall framing.
  • Walls yes, ceilings no: PAC lists walls: Yes and ceilings: No. "Ceiling-wall intersection" does not make this a ceiling suspension clip — it isolates the head of a wall from the overhead structure.
  • Fixed 1/2 in isolation cavity: The system is fixed and non-adjustable, creating a 1/2 in isolation cavity between the wall plate or track and the structure.
  • New construction and retrofit: PAC approves it for both new walls and remodels — the one requirement is that the wall's anchorage points can be built, or rebuilt, to the published detail.
  • Counted at the studs, not by area: Isolators are installed at 16 or 24 in intervals at or near each stud along each isolated boundary. RSIC-FGP is taken off separately, by linear feet of isolated boundary.
$3.99
/ clip

Online orders up to 4,999 pieces. For anything larger, call (415) 864-4440 and we'll price the project with you.

Volume pricing

$3.99 per piece. Order 250+ pieces and pay $3.89 per piece — an extra $0.10 off per piece for each additional 250 pieces, down to a $3.50 per piece floor.

Discounts apply automatically in the cart and count boxes and cases toward the total.

Authorized PAC International DealerWall-frame isolation system — walls onlyLocal pickup: SF, San Leandro, LA
Product Specs

RSIC-WFI Specifications

Product
RSIC-WFI — Wall Frame Isolator system
Use in walls
Yes — wood or steel framed walls
Use in ceilings
No — it isolates the head of a wall, it is not a ceiling suspension clip
New construction / retrofit
Yes / Yes
System parts
Molded-rubber RSIC-WFI isolators plus continuous 1/2 in RSIC-FGP fiberglass pad
Receives furring or hat channel
No — the system isolates wall framing and does not carry gypsum board
Isolator spacing
16 or 24 in intervals at or near each stud, per the approved detail
Isolation cavity
1/2 in, fixed and non-adjustable
Hole — steel track
3/4 in holes drilled at 16 or 24 in intervals at or near studs; insert the isolator with the large side of the rubber inside the track
Hole — wood plate
1 in hole at each 16 or 24 in anchorage position near studs; insert the smaller/threaded side of the isolator through the hole
Structural fastener — steel track detail
Wood minimum #8 x 2-1/2 in coarse; steel minimum #8 x 1-5/8 in fine-thread self-drilling; concrete screw anchor approximately 3/16 x 3 in, or a listed drop-in / bolt option
Structural fastener — wood plate detail
Wood minimum #8 x 4 in coarse; steel minimum #8 x 3-1/4 in fine-thread; concrete screw anchor approximately 3/16 x 4 in, or a listed drop-in / bolt option
Acoustical design load
72 lbs/lf (pounds per linear foot) — a system linear-load criterion, not a per-isolator rating
Perimeter
Airtight acoustical / fire caulking is required at gypsum perimeters
Companion Component

Base connection

1 — Structural floor
Wood, steel or concrete structure below the wall line
2 — Continuous 1/2 in RSIC-FGP pad
Runs the full length of the isolated boundary, supporting the wall framing between isolators; required at the base of wall framing
3 — RSIC-WFI isolator
At each designed anchorage point, the molded rubber isolator passes through a hole in the plate or track and isolates the central structural fastener from the framing
4 — Wood bottom plate or steel floor track
Bears on the FGP pad, never hard on the structure
5 — Wall studs and gypsum
Framed and boarded per the wall design, with perimeters and penetrations caulked airtight
At the head
The same order in reverse: overhead structure → FGP pad → top plate or track, with an RSIC-WFI-isolated anchor at each designed point
Wall-Frame Isolator Estimator

RSIC-WFI Preliminary Isolator and FGP Takeoff

RSIC-WFI isolators are counted along each isolated boundary — at or near every stud, at 24 in intervals or closer — never from wall square footage. The continuous 1/2 in RSIC-FGP pad is a separate, linear-foot takeoff: it supports the wall framing between isolators and is required at the base of wall framing.

Load criterion — confirm before you specify

PAC's current submittal publishes an acoustical design load of 72 lbs/lf — pounds per linear foot of wall, a system criterion, not a per-isolator rating. Final anchor spacing, fastener selection and anchorage still follow PAC's current documents and the project design. The system is fixed and non-adjustable and creates a 0.5 in isolation cavity.

Product Comparison

How RSIC-WFI compares

ModelJob it doesWhere it sitsReceives channelTypical layout
RSIC-WFIthisIsolates wall framing at the floor and head of wallAt the plate or track, with continuous RSIC-FGP pad between framing and structureNoIsolators at 16 or 24 in intervals near each stud
RSIC-1Isolates gypsum board from the stud facesOn the face of the framingYes — 7/8 in, 25 ga furring channelPer the RSIC-1 installation guide
Downloads

Data Sheets & Guides

PAC International — RSIC-WFI System product page
PAC Clips — Data Sheets Library
FAQ

RSIC-WFI — Common Questions

It isolates a wall's framing where that framing meets the structure. When a bottom plate or track is fastened hard to the floor — or a top plate to the deck — vibration flanks straight through that rigid connection. RSIC-WFI puts rubber-isolated anchors at those points and a continuous fiberglass pad under the plate so the framing is supported without a solid path into the structure.