PAC International RSIC-CWB HD/DD DC

The RSIC-CWB HD/DD DC is a 72 lb resilient brace for connecting adjacent wood- or steel-framed walls — or a secondary dropped-ceiling frame — to supporting framing without creating a rigid vibration bridge. Each steel end fastens to a different framing member; the central resilient connection provides heavy-duty, double-deflection isolation, while the DC version carries PAC's deflection-control designation. It is selected when two otherwise-separated framing systems need bracing — not simply because a wall is being soundproofed. It does not accept hat channel and does not carry drywall.

  • Framing to framing, not drywall to framing: One steel wing screws to the first wall's framing, the other to the adjacent wall's framing, and the resilient element in between keeps the two leaves from becoming a rigid pair. Gypsum stays on its own studs or on a separately specified isolation system.
  • 72 lb acoustical design load: PAC publishes a 72 lb per-isolator acoustical design load for both RSIC-CWB HD/DD and HD/DD DC. The standard RSIC-CWB is rated 36 lb.
  • HD / DD / DC decoded: HD is Heavy Duty, DD is Double Deflection, DC is Deflection Control. PAC lists total deflection of 3 mm with double deflection of 1.5 mm; movement criteria for a specific condition should be confirmed with PAC or your design professional.
  • Adjustable across the cavity: PAC lists the isolator as adjustable with a 2 in adjustment limit, over a listed cavity range of about 2 in minimum to 4 in maximum.
  • Shipped assembled and calibrated: The brace arrives fully assembled and calibrated; installation is fastening each end to its framing member with the approved screws.
$18.95
/ clip

Online orders up to 4,999 pieces. For anything larger, call (415) 864-4440 and we'll price the project with you.

Volume pricing

$18.95 per clip. Order 250+ clips and pay $18.65 per clip — an extra $0.30 off per clip for each additional 250 clips, down to a $15.25 per clip floor.

Discounts apply automatically in the cart and count boxes and cases toward the total.

Authorized PAC International DealerFraming-to-framing resilient braceLocal pickup: SF, San Leandro, LA
Product Specs

RSIC-CWB HD/DD DC Specifications

Product type
Resilient cross-wall / chase-wall brace (framing to framing)
Acoustical design load
72 lb per isolator
Total deflection
3 mm (PAC submittal)
Double deflection
Yes — 1.5 mm (PAC submittal)
Adjustable
Yes — 2 in adjustment limit
Cavity range
2 in minimum to 4 in maximum
Framing
Wood or steel
Steel framing minimum
25 Ga. (0.030 in) as stated by PAC — this gauge/thickness pairing is unusual in common gauge nomenclature, so verify the current PAC and project steel thickness requirement
Maximum spacing — vertical
48 in o.c.
Maximum spacing — horizontal
24 in o.c.
End rows
First and last rows within 8 in of floor and ceiling
Fasteners — wood
1 1/4 in minimum coarse-thread screw
Fasteners — steel
#7 × 1/2 in minimum fine-thread screw
Screws per connection point
Minimum 2 (both ends attached: at least 4 per brace)
Nails
Not permitted — approved screws only
Supplied condition
Shipped fully assembled and calibrated
Accepts hat / furring channel
No — it braces framing members, it does not carry drywall
Companion Component

Clip attachment

1 — First wall framing
One perforated steel wing screws flat to a stud or framing member in the first wall
2 — Deflection-control isolator
The central resilient element spans the cavity and keeps the two framing systems separated
3 — Second wall framing
The opposite wing screws to a framing member in the adjacent wall or secondary framed structure
Fasteners
Minimum 2 approved screws at each end — at least 4 per brace; nails are not permitted
Layout
Maximum 24 in horizontal × 48 in vertical, with the first and last rows within 8 in of floor and ceiling
Gypsum
Board stays on its own framing — the brace never receives hat/furring channel or carries drywall
Framing Brace Estimator

RSIC-CWB HD/DD DC Preliminary Estimate

This bracket braces one framing member to another, so the count comes off the bracing grid between opposing framing — not off drywall area. On walls PAC allows brace columns no farther than 24 in apart, rows no farther than 48 in apart, and the first and last rows within 8 in of floor and ceiling. This is a preliminary material takeoff only: the design professional decides whether resilient cross-bracing is required at all and whether the brace loads are acceptable.

Brace positions have to align with framing members that actually face each other across the cavity, so plot them on the framing plan before ordering. Exact framing and end locations can change the count. Brackets are fastened, not cut — there is no waste factor, only the optional ordering allowance above.

Preliminary Material Estimate
Preliminary installed braces21
Order quantity with allowance21
Grid7 columns × 3 rows × 1 section
Minimum framing screws (4 per brace)84
Row heights8, 48, 88 in
Secondary check — area ÷ 8 sq ft96 sq ft → 12
Preliminary material estimate — not a bracing design. Final positions must land on framing members on both sides, wall end rows stay within 8 in of floor and ceiling, and no cabinets, bookshelves or other heavy loads may hang on the braced framing. Nails are never permitted: wood takes a 1 1/4 in minimum coarse-thread screw, steel a #7 × 1/2 in minimum fine-thread screw, with PAC's stated minimum 25 ga (0.030 in) steel — verify that gauge/thickness pairing for your project. Each isolator is limited to a 72 lb acoustical design load; that is a validation check, never the count formula, and the standard RSIC-CWB is distinct from the 72 lb HD/DD and HD/DD DC models. Fire, seismic, structural bracing and load remain project-design responsibilities.
Product Comparison

How RSIC-CWB HD/DD DC compares

ModelWhat It ConnectsAcoustical Design LoadIsolationNotes
RSIC-CWB HD/DD DCthisFraming member to framing member72 lb per isolatorHeavy-duty, double deflection with deflection-control designationChase / cross-wall brace; does not accept furring channel
RSIC-CWB HD/DDFraming member to framing member72 lb per isolatorHeavy duty, double deflectionSame family without the DC designation
RSIC-CWB (standard)Framing member to framing member36 lb per isolatorResilient isolatorBaseline brace for lighter chase / secondary framing conditions
RSIC-1 / Resilmount A237RFraming to furring channel and drywallPer each product's published clip ratingRubber / elastomer clip isolatorDifferent job entirely: these support furring channel and gypsum, while the CWB braces one framing system to another
Downloads

Data Sheets & Guides

PAC Clips — Data Sheets Library
FAQ

RSIC-CWB HD/DD DC — Common Questions

Framing to framing. One perforated steel wing screws to a stud or framing member in the first wall, the central resilient isolator spans the cavity, and the opposite wing screws to a framing member in the adjacent wall or secondary structure. It never receives a hat/furring channel and never carries gypsum directly — the drywall stays on its own studs or on a separately specified isolation system.