PAC International Clips

PAC International RSIC-CWB

The standard RSIC-CWB is a 36 lb resilient brace used between adjacent wood- or steel-framed walls, especially double-stud and chase walls. One steel end fastens to each framing system, while the resilient center connection stabilizes the frames without creating the same rigid vibration bridge as ordinary blocking. It does not accept hat channel and does not carry drywall — the gypsum stays on its own studs or on a separately specified clip-and-channel system.

  • Framing to framing, not drywall to framing: One perforated steel mounting wing screws to a framing member in the first wall, the other to a framing member in the adjacent wall, and the central resilient isolator holds the two leaves in position without tying them rigidly together. If the wall face also uses RSIC-1 with furring channel, that system supports the drywall while the CWB braces the framing — two separate jobs.
  • 36 lb acoustical design load: PAC publishes a 36 lb per-isolator acoustical design load for the standard RSIC-CWB. The HD/DD and HD/DD DC models are rated 72 lb.
  • Side-mounted to the framing members: PAC states the RSIC-CWB isolator installs to the side of the ceiling or wall framing members, for wood or steel framed systems where a dropped ceiling or secondary structure such as a chase wall is needed.
  • Adjustable across the cavity: PAC's submittal lists the isolator as adjustable with a 2 in adjustment limit, over a listed cavity range of about 2 in minimum to 4 in maximum, and a total deflection of 3 mm.
  • Shipped assembled and calibrated: The brace arrives fully assembled and calibrated per PAC's guide; installation is fastening each end to its framing member with the approved screws — minimum two per connection point.
$18.95
/ clip

Online orders up to 4,999 pieces. For anything larger, call (415) 864-4440 and we'll price the project with you.

Volume pricing

$18.95 per clip. Order 250+ clips and pay $18.65 per clip — an extra $0.30 off per clip for each additional 250 clips, down to a $15.25 per clip floor.

Discounts apply automatically in the cart and count boxes and cases toward the total.

Authorized PAC International DealerFraming-to-framing resilient braceLocal pickup: SF, San Leandro, LA
Product Specs

RSIC-CWB Specifications

Product type
Resilient cross-wall / chase-wall brace (framing to framing)
Acoustical design load
36 lb per isolator
Total deflection
3 mm (PAC submittal)
Adjustable
Yes — 2 in adjustment limit
Cavity range
2 in minimum to 4 in maximum
Framing
Wood or steel
Steel framing minimum
Minimum 0.030 in steel per PAC (printed as 25 Ga.) — verify the current PAC gauge/thickness requirement for your project
Maximum spacing — vertical
48 in o.c.
Maximum spacing — horizontal
24 in o.c.
End rows
First and last rows within 8 in of floor and ceiling
Fasteners — wood
1 1/4 in minimum coarse-thread screw
Fasteners — steel
#7 × 1/2 in minimum fine-thread screw
Screws per connection point
Minimum 2 (both ends attached: at least 4 per brace)
Nails
Not permitted — approved screws only
Supplied condition
Shipped fully assembled and calibrated
Accepts hat / furring channel
No — it braces framing members, it does not carry drywall
Companion Component

Clip attachment

1 — First wall framing
One perforated steel wing screws flat to a stud or framing member in the first wall
2 — Resilient isolator
The central rubber isolator spans the cavity and keeps the two framing systems separated
3 — Second wall framing
The opposite wing screws to a framing member in the adjacent wall or secondary framed structure
Fasteners
Minimum 2 approved screws at each end — at least 4 per brace; nails are not permitted
Layout
Maximum 24 in horizontal × 48 in vertical, with the first and last rows within 8 in of floor and ceiling
Gypsum
Board stays on its own framing — the brace never receives hat/furring channel or carries drywall
Framing Brace Estimator

RSIC-CWB Preliminary Estimate

This bracket braces one framing member to another, so the count comes off the bracing grid between opposing framing — not off drywall area. On walls PAC allows brace columns no farther than 24 in apart, rows no farther than 48 in apart, and the first and last rows within 8 in of floor and ceiling. This is a preliminary material takeoff only: the design professional decides whether resilient cross-bracing is required at all and whether the brace loads are acceptable.

Brace positions have to align with framing members that actually face each other across the cavity, so plot them on the framing plan before ordering. Exact framing and end locations can change the count. Brackets are fastened, not cut — there is no waste factor, only the optional ordering allowance above.

Preliminary Material Estimate
Preliminary installed braces21
Order quantity with allowance21
Grid7 columns × 3 rows × 1 section
Minimum framing screws (4 per brace)84
Row heights8, 48, 88 in
Secondary check — area ÷ 8 sq ft96 sq ft → 12
Preliminary material estimate — not a bracing design. Final positions must land on framing members on both sides, wall end rows stay within 8 in of floor and ceiling, and no cabinets, bookshelves or other heavy loads may hang on the braced framing. Nails are never permitted: wood takes a 1 1/4 in minimum coarse-thread screw, steel a #7 × 1/2 in minimum fine-thread screw, with PAC's stated minimum 25 ga (0.030 in) steel — verify that gauge/thickness pairing for your project. Each isolator is limited to a 36 lb acoustical design load; that is a validation check, never the count formula, and the standard RSIC-CWB is distinct from the 72 lb HD/DD and HD/DD DC models. Fire, seismic, structural bracing and load remain project-design responsibilities.
Product Comparison

How RSIC-CWB compares

ModelRoleAcoustical design loadAccepts furring channelWall layout maximum
RSIC-CWBthisResilient framing-to-framing brace (standard)36 lb per isolatorNo24 in horizontal × 48 in vertical
RSIC-CWB HD/DDHeavy-duty / double-deflection framing brace72 lb per isolatorNo24 in horizontal × 48 in vertical
RSIC-CWB HD/DD DCHeavy-duty / double-deflection brace with deflection-control designation72 lb per isolatorNo24 in horizontal × 48 in vertical
RSIC-1Resilient clip that carries isolated drywallSee PAC RSIC-1 documentationYes — 7/8 in 25-ga furring channelSee PAC RSIC-1 documentation
Downloads

Data Sheets & Guides

PAC International — RSIC-CWB Series product page
PAC Clips — Data Sheets Library
FAQ

RSIC-CWB — Common Questions

Framing to framing. One perforated steel mounting wing screws to a stud or framing member in the first wall, the resilient center spans the cavity, and the opposite wing screws to a framing member in the adjacent wall or secondary framed structure. It never receives a hat/furring channel and never carries gypsum directly — the drywall stays on its own studs or on a separately specified isolation system.