PAC International RSIC-SI-X ADM Mini Drop-In
The RSIC-SI-X ADM Mini Drop-In is a ceiling-only spring isolator that threads into a 1/4-inch mini drop-in anchor set in concrete. Its adjustable lower clip receives one 7/8-inch, 25-gauge hemmed-edge furring channel, creating a level, spring-isolated gypsum ceiling below a concrete slab. PAC lists it for ceilings, so it is best kept to ceiling work — a wall calls for a wall-rated system instead.

- "Mini Drop-In" is the anchor: The name describes the 1/4 in mini drop-in anchor set into the slab — not a suspended grid and not a lay-in ceiling tile system.
- Threads straight into the slab: Drill the concrete, set the anchor with its setting tool, thread the adjustable ADM assembly in, and the ceiling hangs from the slab with no wire and no carrier grid.
- Adjustable for a level ceiling: Bend the isolator down parallel with the floor, spin the threaded assembly to the elevation you want, and lock it with the jam nut.
- One furring channel per isolator: The lower clip snaps onto a single 7/8 in, 25-gauge hemmed-edge drywall furring channel at a maximum of 24 in o.c. Gypsum attaches only to the channel.
- Three calibrated springs: Red 26 lb, blue 13 lb and white 7 lb design loads at about 3/8 in deflection from free height — chosen by the load each position actually carries.
Contact for pricing
Special-order item. We confirm current pricing, lead time (typically 3–10 business days, longer for custom sizes), and the material, size and finish options available — plus supply-only vs. professional-install pricing. Nothing is charged until you approve the estimate.
Prefer a form? Open the estimate request with this product filled in.
RSIC-SI-X ADM MINI DROP IN Specifications
- Use on ceilings
- Yes
- Use on walls
- No
- Structure
- Concrete ceilings only — not wood or steel framing, hanger wire or CRC carrier channel
- Type
- Adjustable spring isolator threaded into a concrete mini drop-in anchor
- Anchor
- DeWalt 1/4 in mini drop-in anchor, model 06335-PWR, set with the required setting tool and drill system
- Channel accepted
- One 7/8 in, 25-gauge hemmed-edge drywall furring channel
- Acoustical design load
- 7 – 26 lb per isolator — red 26 lb, blue 13 lb, white 7 lb
- Design load basis
- 3/8 in deflection from free height per the installation guide
- Total deflection
- 3/8 in (submittal)
- Double deflection
- Yes (1.5 mm), per PAC's submittal terminology
- Clip layout
- 16 in × 48 in o.c. or 24 in × 32 in o.c.
- Furring channel spacing
- Maximum 24 in o.c.
- Adjustable
- Yes — threaded rod, locked with a jam/lock nut
- Cavity minimum
- 2 in
- Finished drop
- PAC's current installation guide contains two different drop tables — confirm the bolt length and finished drop with PAC and the project detail
- Gypsum supported
- Up to two layers of 5/8 in when spaced at 16 in × 48 in o.c., subject to the actual dead-load calculation
- Materials
- Steel parts with a rubber and/or manufactured-rubber compound isolator and a coil spring
- Construction
- New construction
- Service conditions
- Interior use only, 40–100°F (4.4–37.8°C)
Channel attachment
- Gauge
- 25 gauge with hemmed edge required; meets or exceeds SSMA
- Depth
- 7/8 in
- Width — top
- 1-1/4 in
- Width — bottom
- 2-9/16 in to 2-11/16 in nominal
- Spacing
- Maximum 24 in o.c.
- Splices
- Minimum 6 in overlap at midspan between two clips — never on a clip — secured with double-wrapped 18-ga tie wire or two 7/16 in framing screws
- Per isolator
- One channel — the clip does not take a second channel, a CRC carrier or hanger wire
RSIC-SI-X ADM Mini Drop-In Preliminary Estimate
Built for ceilings. Quantity and spring colour are two separate checks: the layout sets how many clips you need, and the weight each one actually carries sets whether it is a red 26 lb, blue 13 lb or white 7 lb isolator.
The load figure should cover everything the ceiling permanently carries — the gypsum layers, the furring channel, and any permanently supported items. Both permitted layouts put furring channel no more than 24 in o.c. The count is plotted as channel lines × clips per channel using the offsets shown on PAC's illustrated concrete layout — about 4 in from the side edges and 6 in from the row ends. Confirm those offsets against your own framing and assembly rather than assuming they apply everywhere. Spares are jobsite spares, not cut waste — a clip is never cut.
Both permitted layouts share the same nominal tributary area of 5.333 sq ft per field clip (about 0.1875 clip per sq ft). That division is only a sanity check — the plotted count is what you order from.
A calculated load sits above PAC's largest calibrated 26 lb spring. That is a redesign, not a rounding-up: tighten the layout or lighten the build-up, and confirm with PAC or the project engineer.
How RSIC-SI-X ADM MINI DROP IN compares
| Model | Type | Structure | Supports | Height adjustment |
|---|---|---|---|---|
| RSIC-SI-X ADM Mini Drop-Inthis | Adjustable spring isolator on a 1/4 in mini drop-in anchor | Concrete ceilings only | One 7/8 in furring channel directly; about 2 in minimum cavity | Threaded rod locked with a jam nut |
| RSIC-SI-X ADM Multi Clip | Direct mounting bracket, not the mini drop-in anchor version | Concrete, wood or steel — underside or side of framing | One 7/8 in furring channel directly | Threaded rod locked with a jam nut |
| RSIC-WHI | Rubber isolator installed inline in hanger wire | Ceilings only | A wire-supported drywall or CRC grid — not direct furring | Hanger-wire length |
| RSIC-SI-CRC systems | Spring hangers | Ceilings only | A CRC carrier channel rather than direct furring | By hanger design |
| RSIC-1 Low Profile | Shallow side-of-joist rubber clip | Ceilings only | One 7/8 in furring channel directly | None — no threaded spring adjustment |