(415) 864-4440
PAC International Clips

PAC International RSIC-SI-FF-WRC EZ

The RSIC-SI-FF-WRC EZ is a ceiling-only, wire-hung full-frame spring-and-rubber isolator. Its lower EZ clip snaps onto and is screwed to a 1-1/2 inch, 16-gauge CRC carrier; 7/8 inch furring channels cross the CRC and support the gypsum. PAC lists it for ceilings, so it is best kept to ceiling work — a wall calls for a wall-rated system instead.

  • WRC means wire hung: PAC's guide describes the WRC as a wire-hung spring and rubber isolation system holding CRC channel. Hanger wire or pencil rod carries it from the non-isolated structure above; the BRC EZ is the direct-mount version of the same frame.
  • EZ clip holds the CRC carrier: "EZ" is the lower connection: snap the 1-1/2 x 1/2 in 16 ga cold rolled channel into the EZ clip and screw the channel to the clip. Furring channel does not fasten to the isolator — it crosses the CRC below.
  • Shipped assembled, pre-loaded and calibrated: Each unit arrives fully assembled, pre-loaded and pre-calibrated with a mid-bracket hinge. Verify the capacity and colour of every isolator before installing, and do not disassemble or randomly rotate the clip from its bracket.
  • 10 to 80 lb, 0.50 to 1.00 in deflection: Five calibrated capacities — White 10, Blue 20, Green 30, Red 40 and Silver 80 lb — each with a published 0.50 to 1.00 in deflection range and 1 in total deflection.
  • Built around two 5/8 in gypsum layers: PAC engineers the RSIC-SI-FF for two layers of 5/8 in Fire Code C board, and the pre-calibration is set so the ceiling settles about 5/8 in once that second layer is up.
$51.95
/ clip

Online orders up to 4,999 pieces. For anything larger, call (415) 864-4440 and we'll price the project with you.

Volume pricing

$51.95 per clip. Order 250+ clips and pay $51.45 per clip — an extra $0.50 off per clip for each additional 250 clips, down to a $44.95 per clip floor.

Discounts apply automatically in the cart and count boxes and cases toward the total.

Authorized PAC International DealerCeiling-only wire-hung spring and rubber isolatorLocal pickup: SF, San Leandro, LA
Product Specs

RSIC-SI-FF-WRC EZ Specifications

Use on ceilings
Yes
Use on walls
No
Type
Full-frame spring and rubber isolator, shipped pre-assembled, pre-loaded and pre-calibrated
Upper connection
Wire hung — minimum 12 ga annealed galvanized hanger wire or specified pencil rod tied through the upper eye nut
Lower connection
EZ clip: 1-1/2 x 1/2 in 16 ga cold rolled channel snaps in and is screwed to the clip
Furring channel
7/8 in 20 to 25 ga drywall furring channel wire-tied across the CRC — it never fastens to the isolator
Acoustical design load
10 – 80 lb (White 10 · Blue 20 · Green 30 · Red 40 · Silver 80)
Deflection range
0.50 – 1.00 in
Total deflection
1 in
Double deflection
Yes
Adjustable
Yes — rotate the centre screw clockwise to raise, counter-clockwise to lower
Settlement
Pre-calibrated to deflect about 5/8 in from the preset position after the second gypsum layer
Maximum spacing
48 in o.c. each way mid-room, with drywall grid or cold rolled channel
Perimeter
Isolators not more than 8 in from the isolated-ceiling edge, keeping at least 3 in of clearance
Cavity minimum
12 1/2 in per PAC's specification table
Cavity maximum
Unlimited (set by the wire drop)
Construction
New construction and remodel
Designed for
Two layers of 5/8 in Fire Code C gypsum board
Companion Component

Making the connection

1 — Structure
Non-isolated overhead structure or substrate, with anchors by others approved for the substrate, the shear and the actual load
2 — Hanger wire
Minimum 12 ga annealed galvanized wire per local code, or the specified pencil rod, tied through the upper eye nut above the rubber element
3 — RSIC-SI-FF-WRC EZ
The full-frame spring and rubber isolator, hung on that wire and set so the ceiling can settle about 5/8 in
4 — CRC carrier
1-1/2 x 1/2 in 16 ga cold rolled channel snapped into the lower EZ clip and screwed to it; ends interconnected as normal grid practice
5 — Furring channel
7/8 in 20 to 25 ga drywall furring channel wire-tied across the CRC at 24 in o.c. for one or two gypsum layers, 16 in o.c. for three
6 — Gypsum
Two 5/8 in layers in PAC's design basis, with a 1/8 to 1/4 in perimeter gap sealed with non-hardening acoustical caulk
Ceiling Isolator Estimator

RSIC-SI-FF-WRC EZ Preliminary Estimate

Built for ceilings. Quantity and capacity are two separate checks: the plotted grid sets how many isolators you need, and the weight each position actually carries sets which calibrated capacity goes there.

A two-layer 5/8 in Fire Code C ceiling at 2.5 lb per sq ft per layer is 5 lb per sq ft on its own, which works out to 80 lb on a full 4 x 4 ft field cell. That figure is the gypsum only — the CRC carriers, furring channel, insulation and anything else the ceiling permanently carries add to it, so include them in the load you enter. Focused loads — projectors, HVAC ducting, curtains, heavy fixtures — are never carried by this ceiling; they need separately designed supports.

Preliminary Material Estimate
Isolators (with spares)32
Grid before spares30 isolators
Layout6 rows × 5 columns
Spacing used48 × 48 in o.c.
Wall quantity0 — ceilings only
Sanity check — area ÷ 16 sq ft320 sq ft → 20

That division is only the nominal maximum-grid check. The plotted count is what you order, and perimeter isolators must sit no more than 8 in from the edge of the isolated ceiling while keeping at least 3 in of clearance.

Suspended system below the isolators: about 5 runs of 1-1/2 x 1/2 in 16 ga CRC carrier at 48 in o.c., snapped into the lower EZ clip and screwed to it, with about 11 lines of 7/8 in 20–25 ga drywall furring channel wire-tied across the CRC at 24 in o.c. Channel runs are a rough length check only.
Capacity check
Field tributary16.0 sq ft · 80.0 lb → Silver 80 lb
Edge tributary≈ 40.0 lb → Red 40 lb
Corner tributary≈ 20.0 lb → Blue 20 lb

Mixed capacities are normal: edge and corner positions carry a fraction of a field position, so never order the heaviest isolator everywhere. Every capacity has a 0.50–1.00 in deflection range, and the spring colour and the rubber insert colour are different labels — White 10 and Blue 20 use blue rubber, Green 30 brown, Red 40 green, Silver 80 red.

Preliminary material estimate — not a final engineered reflected-ceiling plan. PAC requires a professional engineer for any non-standard room dimension, PAC submittal or project drawings override these general layout rules, andthe anchors, hanger wire and structure all have to be checked for the load at each position. Spares are spare isolators, not cut waste.
Product Comparison

How RSIC-SI-FF-WRC EZ compares

ModelUpper connectionLower connectionSurfaceCapacitiesDeflection
RSIC-SI-FF-WRC EZthisWire hung — hanger wire or pencil rodEZ clip holding and screwed to a 1-1/2 in 16 ga CRC carrierCeilings only10 · 20 · 30 · 40 · 80 lb0.50 – 1.00 in (1 in total)
RSIC-SI-FF-BRC EZDirect mount to the structureEZ clip holding a 1-1/2 in 16 ga CRC carrierCeilings only10 · 20 · 30 · 40 · 80 lb0.50 – 1.00 in (1 in total)
RSIC-SI-FF-WRWWire hungWire-style lower connection — confirm the exact detail on PAC's drawingCeilings only10 · 20 · 30 · 40 · 80 lb0.50 – 1.00 in
RSIC-SI-FF-BRWDirect mountWire-style lower connection — confirm the exact detail on PAC's drawingCeilings only10 · 20 · 30 · 40 · 80 lb0.50 – 1.00 in
RSIC-SI-WHIBracket screwed to the side of the framingHanger wire below to a CRC carrier or approved drywall gridCeilings onlyCalibrated spring colour per position1 in total · about 1/2 in settlement
RSIC-SI-CRC EZSpring hanger per its own detailA 1-1/2 in 16 ga CRC carrier on the hangerCeilings onlyCalibrated spring colour per positionPer its own specification
Downloads

Data Sheets & Guides

PAC Clips — Data Sheets Library
FAQ

RSIC-SI-FF-WRC EZ — Common Questions

It is made for ceilings. For a wall, a wall-rated system is the way to go. For a resilient wall, specify a wall-rated system such as the applicable tested RSIC-1 wall design.