PAC International RSIC-SI-X ADM Multi-Clip
The RSIC-SI-X ADM Multi Clip is a ceiling-only, adjustable spring mount that fastens directly to concrete, wood, or steel structure. Its lower clip snaps onto one 7/8-inch, 25-gauge hemmed-edge furring channel, while the threaded assembly lets the installer level the isolated gypsum ceiling. PAC lists it for ceilings, so it is best kept to ceiling work — a wall calls for a wall-rated system instead.

- Direct to structure: It fastens to the underside of concrete, wood or steel framing, and can also fasten to the side of a wood or steel joist. There is no hanger wire and no carrier grid.
- Adjustable for a level ceiling: Bend the installed bracket down parallel with the floor, spin the isolator on the threaded rod to the elevation you want, and lock it with the jam nut.
- One furring channel per clip: The lower clip receives a single 7/8 in, 25-gauge hemmed-edge drywall furring channel. "Multi Clip" describes the adaptable mounting configuration, not multiple channels.
- Three calibrated springs: Red 26 lb, blue 13 lb and white 7 lb design loads at 3/8 in deflection from free height — assigned by location, not one colour everywhere.
- Adjustable drop: Minimum cavity about 2-5/8 in. The installation guide's own bolt schedule details drops from roughly 2-1/8 in to 8-1/4 in.
Online orders up to 4,999 pieces. For anything larger, call (415) 864-4440 and we'll price the project with you.
Volume pricing
$17.25 per clip. Order 250+ clips and pay $17.00 per clip — an extra $0.25 off per clip for each additional 250 clips, down to a $15.00 per clip floor.
Discounts apply automatically in the cart and count boxes and cases toward the total.
RSIC-SI-X ADM MULTI CLIP Specifications
- Use on ceilings
- Yes
- Use on walls
- No
- Type
- Adjustable direct-to-structure spring isolation mount for a suspended gypsum ceiling
- Mounts to
- Underside of concrete, wood or steel framing, or the side of a wood or steel joist
- Channel accepted
- One 7/8 in, 25-gauge hemmed-edge drywall furring channel
- Acoustical design load
- 7 – 26 lb per isolator — red 26 lb, blue 13 lb, white 7 lb
- Design load basis
- 3/8 in deflection from free height per the installation guide
- Total deflection
- 1/2 in (submittal)
- Double deflection
- Yes
- Clip layout
- 16 in × 48 in o.c. or 24 in × 32 in o.c.
- Furring channel spacing
- Maximum 24 in o.c.
- Adjustable
- Yes — threaded rod, locked with a jam/lock nut
- Cavity minimum
- About 2-5/8 in
- Cavity maximum
- Submittal advertises up to 12 in; the installation guide's bolt schedule details drops to 8-1/4 in
- Gypsum supported
- Up to two layers of 5/8 in at PAC's layout, subject to the actual dead-load calculation
- Materials
- Steel parts with a rubber and/or manufactured-rubber compound isolator and a coil spring
- Construction
- New construction
- Service conditions
- Interior use only, 40–100°F (4.4–37.8°C)
Clip attachment
- Gauge
- 25 gauge with hemmed edge required; meets or exceeds SSMA
- Depth
- 7/8 in
- Width — top
- 1-1/4 in
- Width — bottom
- 2-9/16 in to 2-11/16 in nominal
- Spacing
- Maximum 24 in o.c.
- Splices
- 6 in overlap at midspan between two clips — never on a clip — secured with double-wrapped 18-ga tie wire or two 7/16 in framing screws
- Per clip
- One channel — the clip does not take a second channel, a CRC carrier or hanger wire
RSIC-SI-X ADM Multi Clip Preliminary Estimate
Built for ceilings. Quantity and spring colour are two separate checks: the layout sets how many clips you need, and the weight each one actually carries sets whether it is a red 26 lb, blue 13 lb or white 7 lb isolator.
The load figure should cover everything the ceiling permanently carries — the gypsum layers, the furring channel, and any permanently supported items. Both permitted layouts put furring channel no more than 24 in o.c. The count is plotted as channel lines × clips per channel using the offsets shown on PAC's illustrated concrete layout — about 4 in from the side edges and 6 in from the row ends. Confirm those offsets against your own framing and assembly rather than assuming they apply everywhere. Spares are jobsite spares, not cut waste — a clip is never cut.
Both permitted layouts share the same nominal tributary area of 5.333 sq ft per field clip (about 0.1875 clip per sq ft). That division is only a sanity check — the plotted count is what you order from.
A calculated load sits above PAC's largest calibrated 26 lb spring. That is a redesign, not a rounding-up: tighten the layout or lighten the build-up, and confirm with PAC or the project engineer.
How RSIC-SI-X ADM MULTI CLIP compares
| Model | Type | Surfaces | Supports | Load | Height adjustment |
|---|---|---|---|---|---|
| RSIC-SI-X ADM Multi Clipthis | Direct-to-structure adjustable spring and rubber isolator | Ceilings only | One 7/8 in furring channel directly | Red 26 · blue 13 · white 7 lb, location-specific | Threaded rod with jam nut |
| RSIC-WHI | Rubber isolator installed inline in hanger wire | Ceilings only | A wire-supported drywall or CRC grid — not direct furring | 15–220 lb across six versions | Hanger-wire length |
| RSIC-1 Low Profile | Shallow side-of-joist rubber clip | Ceilings only | One 7/8 in furring channel directly | 36 lb design load | None — no threaded spring adjustment |
| RSIC-SI-CRC systems | Spring hangers | Ceilings only | A CRC carrier channel rather than direct furring | Calibrated spring versions by model | By hanger design |