PAC International Clips

PAC International RSIC-WHI

The RSIC-WHI is a ceiling-only rubber isolator installed inline in hanger wire. It resiliently separates a suspended drywall grid — or a CRC-and-furring-channel ceiling — from the structure. Choose the color/load version from the actual weight carried by each hanger, not from ceiling area alone. PAC lists it for ceilings, so it is best kept to ceiling work — a wall calls for a wall-rated system instead.

  • Installed mid-wire: It sits in the middle of the hanger wire between the structure and a dropped drywall grid or CRC ceiling. It does not screw to a stud and does not directly accept 7/8 in hat channel.
  • Two wire loops, one rubber isolator: Upper and lower wire loops are separated by the rubber isolator, and the hanger assembly tolerates up to 15 degrees of hanger-wire misalignment without metal-to-metal contact.
  • Any structure, with the right anchor above: Wood, steel, metal deck or concrete — the bracket or anchor above the wire is chosen for that substrate; the isolator itself is unchanged.
  • Six load versions: Blue 30, Brown 50, Green 70, Red 100, White 145 and Yellow 220 lb, each designed to work between 50% and 100% of its published load.
  • Adjustable through wire length: Minimum ceiling cavity is 4 in; the maximum is set by how long the hanger wire is. Deflection at full published load is up to 1/4 in (6 mm).
Price Available on Request

Contact for pricing

Special-order item. We confirm current pricing, lead time (typically 3–10 business days, longer for custom sizes), and the material, size and finish options available — plus supply-only vs. professional-install pricing. Nothing is charged until you approve the estimate.

Call (415) 864-4440

Prefer a form? Open the estimate request with this product filled in.

Authorized PAC International DealerCeiling-only wire hanger isolatorLocal pickup: SF, San Leandro, LA
Product Specs

RSIC-WHI Specifications

Use on ceilings
Yes
Use on walls
No
Type
Wire hanger isolator — two wire loops separated by a rubber isolator
Installed position
Mid-wire, between the structure and a suspended drywall grid or CRC and furring-channel ceiling
Structure
Wood, steel, metal deck or concrete, using a substrate-appropriate bracket or anchor above the wire
Hanger wire
Minimum 12-ga annealed, tied with a minimum of 3 turns at each connection
Misalignment allowed
Up to 15 degrees of suspension misalignment without metal-to-metal contact
Acoustical design load
15 to 220 lb across six versions — each works between 50% and 100% of its published load
Load versions
Blue WHI-30 15–30 · Brown WHI-50 25–50 · Green WHI-70 35–70 · Red WHI-100 50–100 · White WHI-145 72–145 · Yellow WHI-220 110–220 lb
Total deflection at load
Up to 1/4 in (6 mm) at full published load
Double deflection
N/A
Maximum spacing
48 in × 48 in o.c., with the first and last rows within 8 in of the wall
Cavity minimum
4 in
Cavity maximum
No limit — controlled by hanger-wire length
Adjustable
Yes — through hanger-wire length
Construction
New construction and retrofit
Materials
Galvanized or aluminum-zinc coated steel with a natural or manufactured rubber isolator
Service conditions
Interior use only, 40–100°F (4.4–37.8°C)
Overall size
3 7/8 in tall × 1 1/2 in wide per PAC's drawing
Companion Component

Making the connection

1 — Structure
Wood, steel, metal deck or concrete
2 — Attachment
A bracket or anchor selected for that substrate — wire, screws, bolts or expansion anchors
3 — Upper wire
Minimum 12-ga annealed hanger wire, minimum 3 turns at the mounting bracket
4 — RSIC-WHI
Tied through the isolator's existing wire loop, minimum 3 turns
5 — Lower wire
Minimum 12-ga annealed hanger wire down to the ceiling grid, minimum 3 turns at the grid
6 — Grid
Drywall grid ceiling, or a CRC carrier grid — installed to that manufacturer's own instructions
7 — Furring channel
Where the ceiling design uses it, 7/8 in furring channel crosses the carriers within that grid system — it never fastens to the isolator
8 — Gypsum
Attaches to the grid or furring channel, with a 1/4 in perimeter gap for sealant
Ceiling Isolator Estimator

RSIC-WHI Preliminary Estimate

Built for ceilings — a resilient wall calls for a wall-rated system instead. Quantity and load version are two separate checks. The grid sets how many isolators you need; the weight each one actually carries sets which color you order.

The load figure should cover everything the ceiling permanently carries — gypsum layers, the drywall grid or CRC and furring channels, and any permanently supported items. Count comes from rows × columns with the first and last rows within 8 in of the walls, so a finite room normally needs more isolators than a plain area division suggests. Heavy concentrated loads, obstructions, grid and carrier spans, and the capacity of the structure and its anchors can all require extra or repositioned hangers and engineering. Spares are spare isolators, not cut waste — an isolator is never cut.

Preliminary Material Estimate
Isolators (with spares)32
Grid before spares30 isolators
Layout6 rows × 5 columns
Spacing used48 × 48 in o.c.
Sanity check — area ÷ 16 sq ft320 sq ft → 20

That division is only the nominal maximum-grid check. The plotted count is normally higher because the edge rows and columns must sit within 8 in of the walls.

Load version check
Interior tributary16.0 sq ft · 80.0 lb
Corner tributary≈ 20.0 lb
Selected versionRed WHI-100 — 50 to 100 lb
Fits the interior tributaryRed WHI-100

Perimeter and corner positions carry less than half of an interior position, so they can fall below this version's 50% working floor. An engineered hanger plan may specify a lighter-rated version at those positions.

Preliminary material estimate — not a final engineered hanger plan. Every isolator must work between 50% and 100% of its published acoustical design load, and a single color may not suit every position on the ceiling.
Product Comparison

How RSIC-WHI compares

ModelTypeSurfacesSupportsLoadMovement
RSIC-WHIthisRubber wire-insert hanger isolatorCeilings onlyWire-supported drywall grid or CRC and furring grid15–220 lb working ranges across six versionsUp to 1/4 in deflection · 4 in minimum cavity
RSIC-SI-CRC EZCoil-spring ceiling hangerCeilings onlyA CRC carrier directly on the hangerCalibrated 5–80 lb spring versionsGreater spring movement and cavity than the WHI
RSIC-SI-CRC2 LPLow-profile spring hangerCeilings onlyTwo parallel CRC carriers, anchored to concreteCalibrated 10–120 lb spring versionsAbout 3 7/8 in minimum cavity
RSIC-1 Low ProfileRubber isolation clipCeilings only7/8 in furring channel directly, on the side of the joist36 lb design loadNo suspended wire or CRC grid — much smaller ceiling drop
Downloads

Data Sheets & Guides

PAC Clips — Data Sheets Library
FAQ

RSIC-WHI — Common Questions

It is made for ceilings. For a wall, a wall-rated system is the way to go. For a resilient wall, specify a wall-rated system such as the applicable tested RSIC-1 wall design.