PAC International Clips

PAC International RSIC-SI-FF-BRC EZ

The RSIC-SI-FF-BRC EZ is the direct-mount BRC EZ version of PAC's full-frame spring-and-rubber ceiling isolator: it fastens straight to an approved non-isolated structure above instead of hanging on wire. Its lower EZ clip snaps onto and is screwed to a 1-1/2 inch, 16-gauge cold rolled channel carrier; 7/8 inch drywall furring channels cross beneath that CRC and carry the gypsum. PAC lists it for ceilings, so it is best kept to ceiling work — a wall calls for a wall-rated system instead.

  • Direct-mount BRC EZ: BRC EZ is the direct-mounted member of the RSIC-SI-FF family: the upper bracket is fastened to an approved non-isolated structure or substrate with a project-approved anchor by others. PAC does not publish a word expansion for the letters, so none is invented here.
  • EZ clip holds the CRC carrier: "EZ" is the lower connection: snap the 1-1/2 x 1/2 in 16 ga cold rolled channel into the EZ clip and screw the channel to the clip. Furring channel does not fasten to the isolator — it crosses beneath the CRC.
  • Adjustable, pre-assembled and pre-calibrated: Each unit ships fully assembled, pre-loaded and pre-calibrated with an adjustable centre leveling rod — clockwise raises the ceiling, counter-clockwise lowers it. Do not rotate the clip from its bracket or separate the calibrated unit.
  • 10 to 80 lb acoustical design load: Factory-calibrated capacities: White 10, Blue 20, Green 30, Red 40 and Silver 80 lb. Select each position from the tributary dead load it actually carries via the PAC or project submittal.
  • Built around two 5/8 in gypsum layers: PAC engineers the RSIC-SI-FF EZ around two layers of 5/8 in Type C fire-code gypsum, and the pre-calibration allows a nominal 5/8 in of settling once that second layer is up.
Price not confirmed

Price not confirmed

We couldn’t confirm the current price. No payment was taken. Please retry or call us at (415) 864-4440.

Authorized PAC International DealerCeiling-only direct-mount spring and rubber isolatorLocal pickup: SF, San Leandro, LA
Product Specs

RSIC-SI-FF-BRC EZ Specifications

Use on ceilings
Yes
Use on walls
No
Type
Full-frame spring and rubber isolator, shipped pre-assembled, pre-loaded and pre-calibrated
Upper connection
Direct mount — the upper bracket is fastened to an approved non-isolated structure or substrate with project-approved anchors by others
Lower connection
EZ clip: 1-1/2 x 1/2 in 16 ga cold rolled channel snaps in and is screwed to the clip
Furring channel
7/8 in 20 to 25 ga drywall furring channel wire-tied perpendicular across the CRC — it never fastens to the isolator
Acoustical design load
10 – 80 lb (White 10 · Blue 20 · Green 30 · Red 40 · Silver 80)
Total deflection
1 in
Settlement
Allow a nominal 5/8 in of settling from the preloaded position after the second gypsum layer
Adjustable
Yes — rotate the centre screw clockwise to raise, counter-clockwise to lower
Maximum spacing
48 in o.c. each way
Perimeter
The first support is less than 8 in from the wall unless an approved wall-angle detail is used
Cavity minimum
12 1/2 in per PAC's WRC/BRC EZ specification table
Cavity maximum
Unlimited
Furring spacing
24 in o.c. for one or two gypsum layers; 16 in o.c. for three layers, subject to project-specific approval
Designed for
Two layers of 5/8 in Type C fire-code gypsum board
Companion Component

Making the connection

1 — Structure
Approved non-isolated overhead structure or substrate with project-approved fasteners/anchors by others, verified for the pull-out, shear and actual load
2 — RSIC-SI-FF-BRC EZ
The upper mounting bracket and full-frame rubber-and-spring isolator, mounted directly to that structure
3 — Centre leveling rod
The adjustable centre rod between the isolator and the lower clip; clockwise raises, counter-clockwise lowers
4 — RSIC-EZ clip and CRC carrier
1-1/2 x 1/2 in 16 ga cold rolled channel snapped into the lower EZ clip and mechanically screwed to it
5 — Furring channel
7/8 in 20 to 25 ga drywall furring channels run perpendicular and wire-tied to the CRC — 24 in o.c. for one or two gypsum layers, 16 in o.c. for three
6 — Gypsum
Two 5/8 in Type C layers in PAC's design basis, held off the walls with 1/8 to 1/4 in of perimeter separation (the specification uses 1/4 in), perimeter isolation tape and non-hardening acoustical sealant
Ceiling Isolator Estimator

RSIC-SI-FF-BRC EZ Preliminary Estimate

Built for ceilings. Quantity and capacity are two separate checks: the plotted grid sets how many isolators you need, and the weight each position actually carries sets which calibrated capacity goes there.

A two-layer 5/8 in Fire Code C ceiling at 2.5 lb per sq ft per layer is 5 lb per sq ft on its own, which works out to 80 lb on a full 4 x 4 ft field cell. That figure is the gypsum only — the CRC carriers, furring channel, insulation and anything else the ceiling permanently carries add to it, so include them in the load you enter. Focused loads — projectors, HVAC ducting, curtains, heavy fixtures — are never carried by this ceiling; they need separately designed supports.

Preliminary Material Estimate
Isolators (with spares)32
Grid before spares30 isolators
Layout6 rows × 5 columns
Spacing used48 × 48 in o.c.
Wall quantity0 — ceilings only
Sanity check — area ÷ 16 sq ft320 sq ft → 20

That division is only the nominal maximum-grid check. The plotted count is what you order, and perimeter isolators must sit no more than 8 in from the edge of the isolated ceiling while keeping at least 3 in of clearance.

Suspended system below the isolators: about 5 runs of 1-1/2 x 1/2 in 16 ga CRC carrier at 48 in o.c., snapped into the lower EZ clip and screwed to it, with about 11 lines of 7/8 in 20–25 ga drywall furring channel wire-tied across the CRC at 24 in o.c. Channel runs are a rough length check only.
Capacity check
Field tributary16.0 sq ft · 80.0 lb → Silver 80 lb
Edge tributary≈ 40.0 lb → Red 40 lb
Corner tributary≈ 20.0 lb → Blue 20 lb

Mixed capacities are normal: edge and corner positions carry a fraction of a field position, so never order the heaviest isolator everywhere. Every capacity has a 0.50–1.00 in deflection range, and the spring colour and the rubber insert colour are different labels — White 10 and Blue 20 use blue rubber, Green 30 brown, Red 40 green, Silver 80 red.

Preliminary material estimate — not a final engineered reflected-ceiling plan. PAC requires a professional engineer for any non-standard room dimension, PAC submittal or project drawings override these general layout rules, andthe structure and the project-approved anchors have to be checked for pull-out, shear and the actual load at each position. Spares are spare isolators, not cut waste.
Product Comparison

How RSIC-SI-FF-BRC EZ compares

ModelUpper connectionLower connectionSurfaceCapacitiesDeflection
RSIC-SI-FF-BRC EZthisDirect mount to an approved non-isolated structureEZ clip holding and screwed to a 1-1/2 in 16 ga CRC carrierCeilings only10 · 20 · 30 · 40 · 80 lb1 in total · nominal 5/8 in settling after boarding
RSIC-SI-FF-WRC EZWire hung — hanger wire or pencil rodEZ clip holding a 1-1/2 in 16 ga CRC carrierCeilings only10 · 20 · 30 · 40 · 80 lb1 in total
RSIC-SI-FF-BRWDirect mountLower hanger wire to a suspended drywall gridCeilings only10 · 20 · 30 · 40 · 80 lbPer its own specification
RSIC-SI-FF-WRWWire hungLower hanger wire to a suspended drywall gridCeilings only10 · 20 · 30 · 40 · 80 lbPer its own specification