The RSIC-SI-CRC2 LP is a ceiling-only, low-profile spring hanger for concrete structures. Each hanger supports two parallel 1 1/2 in, 16-gauge cold rolled carrier channels; 7/8 in drywall furring channels cross those carriers and support the gypsum. The double-CRC arrangement allows wider hanger spacing while providing calibrated spring isolation in approximately a 3 7/8 in minimum cavity. PAC lists it for ceilings — for a resilient wall, specify a wall-rated system instead.

  • Hangs from concrete: The preassembled hanger threads onto a mini or standard 1/4 in or 3/8 in drop-in anchor set in the concrete slab or deck. It is not anchored to wood or light-gauge framing.
  • Two CRC carriers per hanger: "CRC2" means it carries two parallel 1 1/2 in, 16-ga cold rolled channels, which is what permits the wider hanger spans and layout flexibility.
  • Not a CRC-to-hat coupler: The sequence is concrete → anchor → spring hanger → two CRC carriers → 7/8 in drywall furring channel crossing the CRC → gypsum. Furring channel never fastens to the hanger.
  • Low profile, about 3 7/8 in: PAC lists a 3 7/8 in minimum cavity. It is low profile relative to other spring suspension systems — not as shallow as an RSIC-1 Low Profile clip.
  • Preassembled and precalibrated: Ships assembled with a color-coded calibrated spring, 10 lb through 120 lb, selected for the tributary ceiling load at each hanger position.
$50.95
/ clip

Online orders up to 4,999 pieces. For anything larger, call (415) 864-4440 and we'll price the project with you.

Volume pricing

$50.95 per clip. Order 250+ clips and pay $50.45 per clip — an extra $0.50 off per clip for each additional 250 clips, down to a $44.40 per clip floor.

Discounts apply automatically in the cart and count boxes and cases toward the total.

Authorized PAC International DealerCeiling-only spring hangerLocal pickup: SF, San Leandro, LA
Product Specs

RSIC-SI-CRC2 LP Specifications

Use on ceilings
Yes
Use on walls
No
Structure
Concrete slab or deck, via a mini or standard 1/4 in or 3/8 in drop-in anchor
Acoustical design load
Calibrated versions, 10 lb to 120 lb
Spring colors
White 10 · Blue 20 · Green 30 · Red 40 · Purple 60 · Silver 80 · Orange 100 · Gold 120 lb
Source conflict — 160 lb
The installation guide depicts a Black 160 lb spring; the product specification stops at 120 lb. Not sold as a standard selection without written PAC confirmation.
Carriers supported
Two parallel 1 1/2 in, 16-ga cold rolled channels (CRC)
Maximum hanger spacing
Sources conflict: 72 in × 48 in o.c. on the submittal cover, main instructions and sample layout; 60 in × 48 in o.c. on one guide bullet
Total deflection
7/8 in on the submittal; the guide describes the system as a 1 in deflection dropped ceiling
Loaded settlement
Precalibrated to settle about 1/2 in below the preset height once the second layer of 5/8 in gypsum is on
Cavity minimum
3 7/8 in
Cavity maximum
Bolt length
Height adjustment
Move the CRC up or down on the hanger side flange — the guide shows roughly 3 5/16 in to 4 5/16 in positions
Preassembled / precalibrated
Yes — do not rotate or separate the clip from the upper bracket
Construction
New construction
Recommended ceiling mass
Minimum two layers of 5/8 in gypsum board or equal mass
Companion Component

Channel grid

Carrier channel
Two parallel 1 1/2 in, 16-ga cold rolled channels, nominal 1/2 in × 1 1/2 in × 1/2 in, SSMA 150U050-54
CRC attachment
Each CRC is permanently fastened to the hanger side flange with minimum 1/2 in self-drilling framing screws — screws must not contact the springs
Drywall furring channel
Minimum 20-ga standard per the current guide, meeting or exceeding SSMA · 7/8 in deep
Furring channel width
Bottom 2 9/16 in to 2 11/16 in nominal · top 1 1/4 in
Furring channel attachment
Wire tied or screwed across the CRC carriers — max 24 in o.c., PAC recommends 16 in o.c. for two layers of gypsum
Furring channel splice
6 in overlap at midspan — double-wrapped 18-ga tie wire or two 7/16 in framing screws
Gypsum
Attaches to the furring channel only, never to the spring hanger
Ceiling Hanger Estimator

RSIC-SI-CRC2 LP Preliminary Estimate

Built for ceilings — a resilient wall calls for a wall-rated system instead. Quantity comes off the hanger grid: each hanger supports two parallel 1-1/2 in, 16-ga cold rolled carrier channels, with 7/8 in drywall furring channel crossing them below.

PAC's principal layout instructions show a 72 × 48 in maximum, while one technical bullet states 60 × 48 in with two cold rolled channels. Confirm the project spacing with PAC. Until it is confirmed, this estimator uses the more conservative 60 × 48 grid.

The real count is plotted on a reflected ceiling plan, not divided out of area: lay out the actual carrier runs, hanger rows and boundary positions, keep the first drywall support 8 in or less from the perimeter, and add or relocate hangers around HVAC, ducting and other obstructions and wherever carrier or furring spans require it. Spares are spare hangers, not cut waste — a hanger is never cut. PAC directs nonstandard room dimensions to a professional engineer.

Preliminary Material Estimate
Hangers (with spares)27
Grid before spares25 hangers
Grid used60 in along × 48 in across
Carrier lines5
Hangers per line5
1-1/2 in CRC — two carriers per line≈ 200 lin ft
Sanity check — area ÷ 20 sq ft320 sq ft → 16
Spring selection check
Load used7.00 lb/sq ft
Tributary per hanger20.0 sq ft · 140.0 lb
Starting springBeyond the 120 lb published range — engineer required

Published calibrated versions are White 10, Blue 20, Green 30, Red 40, Purple 60, Silver 80, Orange 100 and Gold 120 lb. PAC's installation guide also depicts a Black 160 lb spring while the product specification stops at 120 lb — we do not sell 160 lb as a standard selection unless PAC confirms availability and suitability in writing.

Preliminary material estimate — not a final engineered reflected ceiling plan. Quantity and spring calibration are separate checks: the grid sets the count, and every hanger's tributary load — the complete ceiling and any approved equipment load inside its tributary area — must sit within its calibrated rating without exceeding it.
Product Comparison

How RSIC-SI-CRC2 LP compares

ModelTypeSurfacesStructureSupportsLoad
RSIC-SI-CRC2 LPthisLow-profile spring hangerCeilings onlyConcrete, 1/4 in or 3/8 in drop-in anchorTwo parallel 1 1/2 in, 16-ga CRC carriers, wider engineered gridCalibrated 10 / 20 / 30 / 40 / 60 / 80 / 100 / 120 lb versions
RSIC-SI-CRC EZSpring isolation hangerCeilings onlyWood or steel structureOne 1 1/2 in, 16-ga CRC carrier, max 48 × 48 in grid, greater cavityCalibrated 5 / 10 / 20 / 40 / 80 lb versions
RSIC-1 Low ProfileRubber isolation clipCeilings onlySide of the joist7/8 in drywall furring channel directly — no CRC carrier grid, much smaller ceiling drop36 lb design load
Downloads

Data Sheets & Guides

PAC Clips — Data Sheets Library
FAQ

RSIC-SI-CRC2 LP — Common Questions

No. PAC lists it for ceilings — A resilient wall calls for a wall-rated system instead.For a resilient wall, specify a wall-rated system such as the applicable tested RSIC-1 wall design.